Název * : Calculation of the Pulse Wave Velocity from the Waveform of the Central Aortic Pressure Pulse in Young Adults
Citace : Závodná, E., Moudr, J., Honzíková, N. a Fišer, B. Calculation of the Pulse Wave Velocity from the Waveform of the Central Aortic Pressure Pulse in Young Adults. In: Computing in Cardiology 2015 2015-09-06 Niece, France. Niece, France: Computing in Cardiology 2015, 2015. s. 385-388. ISBN 978-1-5090-0684-7.
Podnázev :
Rok * : 2015
Obor * : Fyziologie
Počet stran * : 4
Strana od * : 385
Strana do * : 388
Forma vydání * : Elektronická verze
Kód ISBN * : 978-1-5090-0684-7
Kód ISSN :
Název sborníku * : Computing in Cardiology 2015
Sborník : Mezinárodní
Název nakladatele * : Computing in Cardiology 2015
Místo vydání * : Niece, France
Stát vydání : Sborník vydaný v zahraničí
Název konference :
Místo konání konference * : Niece, France
Datum zahájení konference * :
Typ akce podle státní
příslušnosti účastníků akce * :
Celosvětová akce
Kód UT WoS : :000380374700098
EID :
Klíčová slova anglicky * :
central blood pressure; pulse wave analysis; pulse wave velocity
Popis v původním jazyce * :
Cardiovascular diseases are the most common causes of morbidity and mortality in developed countries. Therefore, the correct determination of the parameters indicating the disease condition is critical in effective treatment of patients [6, 10 - 12]. One of the parameters evaluating arterial stiffness is determining the pulse wave velocity (PWV), but the method of determining faces a number of problems. In the study was measured 20 healthy patients (15-23). Using applanation tonometry was measured pulse wave from a. radialis and a. carotis. PWV was measured by SphygmoCor and calculated by method of flow tringle using aortic pressure pulse for determination PWV. Average value of PWV calculated by method of flow triangle was 8.35 +/- 0.86 m/s and average value measured by SphygmoCor 7.2 +/- 0.8 m/s. The variance differences of measured and calculated values PWV was 0.785 +/- 0.575 m/s. The average value of the a. radialisa. carotis distance was 485 +/- 43.4 mm. According to the results it can be assumed that the new method of analysis the forward and backward waves is relatively accurate, but it is very sensitive to standardize measurement. The results are affected by several factors, is necessary to propose further steps to accurate protocol for the more precise results.
Popis v anglickém jazyce * :
Typ zdroje financování výsledku * :
Seznam projektů :
ID Projektu Název projektu
Seznam ohlasů : 
Ohlas
R01:

© 2019 Centre for Information Technology

  • Technická podpora :
  • Mgr. Olga Blahutová (phone: +420 597 091 129, phone flap for UO: 1129)
  • Ing. Lucie Svitaneková (phone: +420 597 091 108, phone flap for UO: 1108)
Complementary Content
  • ${title}${badge}
${loading}