OU Portal
  • Log In
  • Welcome
  • Applicants
Z6_60GI02O0O8IDC0QEJUJ26TJDI4
{}
Zavřít
Publikační činnost


preloading...   Probíhá načítání, čekejte prosím...
publicationId :
tempRecordId :
actionDispatchIndex :
navigationBranch :
pageMode :
tabSelected :
isRivValid :
Typ záznamu * : stať ve sborníku (D)
Domácí pracoviště * : Katedra studií lidského pohybu (45050)
Název * : Bionic knees allow of symmetrical temporal-spatial parameters of gait compared to mechanically passive knees designs
Citace : Uchytil, J., Jandačka, D., Zahradník, D., Farana, R. a Janura, M. Bionic knees allow of symmetrical temporal-spatial parameters of gait compared to mechanically passive knees designs. In: eProceedings of the 30th Conference of the International Society of Biomechanics in Sports. Australian Catholic University, Melbourne, 115 Victoria Parade, Fitzroy, VIC 3065, Melbourne, Australia., 2012. s. 171-174. ISBN 978-1-922097-00-2.
Podnázev :
Rok * : 2012
Obor * : Sport a aktivity volného času
Počet stran * : 4
Strana od * : 171
Strana do * : 174
Forma vydání * : Tištená verze
Kód ISBN * : 978-1-922097-00-2
Kód ISSN :
Název sborníku * : eProceedings of the 30th Conference of the International Society of Biomechanics in Sports
Sborník : Mezinárodní
Název nakladatele * : Australian Catholic University, Melbourne, 115 Victoria Parade, Fitzroy, VIC 3065, Melbourne, Australia.
Místo vydání * : Neuveden
Stát vydání : Sborník vydaný v zahraničí
Název konference : 30th Conference of the International Society of Biomechanics in Sports
Místo konání konference * : Melbourne, Australia
Datum zahájení konference * :
Typ akce podle státní
příslušnosti účastníků akce * :
Celosvětová akce
Kód UT WoS :
EID :
Klíčová slova anglicky * :
gait, amputees, prosthesis, kinematic analysis, bionic
Popis v původním jazyce * :
The purpose of this study was to compare the basic temporal-spatial parameters of gait and gait symmetry in transfemoral amputees with a bionic knee joint with those in patients using a mechanically passive joint in relation to non-pathological gait. Seven subjects with a transfemoral amputation participated in this study. The amputee subjects performed fifteen attempts to walk across two Kistler force plates embedded in the floor. Objective gait measurements were acquired with a computerized video motion analysis system utilizing seven infrared cameras (Qualisys). Gait with a bionic knee joint showed greater symmetry than gait with a mechanically passive joint. When using a bionic knee joint, the stance and swing times approximated those in people without pathology.
Popis v anglickém jazyce * :
Typ zdroje financování výsledku * : Specifický výzkum
Seznam projektů :
ID Projektu Název projektu
Seznam ohlasů : 
Ohlas
R01: RIV/61988987:17450/12:A13014VR

© 2019 Centre for Information Technology

  • Technická podpora :
  • Mgr. Olga Blahutová (phone: +420 597 091 129, phone flap for UO: 1129)
  • Ing. Lucie Svitaneková (phone: +420 597 091 108, phone flap for UO: 1108)
Complementary Content
  • ${title}${badge}
${loading}