OU Portal
  • Log In
  • Welcome
  • Applicants
Z6_60GI02O0O8IDC0QEJUJ26TJDI4
{}
Zavřít
Publikační činnost


preloading...   Probíhá načítání, čekejte prosím...
publicationId :
tempRecordId :
actionDispatchIndex :
navigationBranch :
pageMode :
tabSelected :
isRivValid :
Typ záznamu * : stať ve sborníku (D)
Domácí pracoviště * : Katedra studií lidského pohybu (45050)
Název * : Evaluation of mechanical power output measurement at bench press exercise under variable load
Citace : Jandačka, D. a Vaverka, F. Evaluation of mechanical power output measurement at bench press exercise under variable load. In: 27 International Conference on Biomechanics in Sports (2009). s. 187-188. ISSN 1999-4168.
Podnázev :
Rok * : 2009
Obor * : Sport a aktivity volného času
Počet stran * : 1
Strana od * : 187
Strana do * : 188
Forma vydání * :
Kód ISBN * :
Kód ISSN : 1999-4168
Název sborníku * : 27 International Conference on Biomechanics in Sports (2009)
Sborník : Mezinárodní
Název nakladatele * : Neuveden
Místo vydání * : Irsko
Stát vydání : Sborník vydaný v zahraničí
Název konference : International society of biomechanics in sports conference 2009
Místo konání konference * : Irsko Limerick
Datum zahájení konference * :
Typ akce podle státní
příslušnosti účastníků akce * :
Celosvětová akce
Kód UT WoS :
EID :
Klíčová slova anglicky * :
bench press power output Evaluation
Popis v původním jazyce * :
The study is aimed to confirm evaluation of mechanical power output measurement during bench press exercise by methods which are used at training practice. This study was performed on ten untrained middle-aged men. The power output was measured at following loads: 18.0; 26.5; 39.2 and 47.7 kg. Method, which employs indirect power output measurement (used in training practice), was performed on FitroDyne Premium equipment. At combined method of mechanical power output measurement we used system Qualisys. For direct force measurement a dynamometric platform AMTI was used.An average mechanic power output measured by an indirect method was significantly lower at loads 18.0 and 26.5 kg, than the power output measured by a combined method (Effect of size = 1.41 and 0.59). This undervaluation can influence the load optimalization at power training.
Popis v anglickém jazyce * :
Typ zdroje financování výsledku * : Projekty CEP/Záměry CEZ
Seznam projektů :
ID Projektu Název projektu
Seznam ohlasů : 
Ohlas
R01: RIV/61988987:17450/09:A1000VGB

© 2019 Centre for Information Technology

  • Technická podpora :
  • Mgr. Olga Blahutová (phone: +420 597 091 129, phone flap for UO: 1129)
  • Ing. Lucie Svitaneková (phone: +420 597 091 108, phone flap for UO: 1108)
Complementary Content
  • ${title}${badge}
${loading}