OU Portal
Log In
Welcome
Applicants
Z6_60GI02O0O8IDC0QEJUJ26TJDI4
Error:
Javascript is disabled in this browser. This page requires Javascript. Modify your browser's settings to allow Javascript to execute. See your browser's documentation for specific instructions.
{}
Zavřít
Publikační činnost
Probíhá načítání, čekejte prosím...
publicationId :
tempRecordId :
actionDispatchIndex :
navigationBranch :
pageMode :
tabSelected :
isRivValid :
Typ záznamu
*
:
stať ve sborníku (D)
Domácí pracoviště
*
:
Ústav pro výzkum a aplikace fuzzy modelování (94410)
Název
*
:
Replacing goniophotometer with camera and U-Net with Hypercolumn rescale block
Citace :
Vajgl, M. a Hurtík, P. Replacing goniophotometer with camera and U-Net with Hypercolumn rescale block.
In:
IWANN 2023 / 17th International Work-Conference on Artifical Neural Networks: 2023-06-18 Ponta Delgada.
s. 1-13.
Podnázev :
Rok
*
:
2023
Obor
*
:
Počet stran
*
:
13
Strana od
*
:
1
Strana do
*
:
13
Forma vydání
*
:
Tištená verze
Kód ISBN
*
:
Kód ISSN :
Název sborníku
*
:
Sborník :
Mezinárodní
Název nakladatele
*
:
Místo vydání
*
:
Stát vydání :
Název konference :
IWANN 2023 / 17th International Work-Conference on Artifical Neural Networks
Místo konání konference
*
:
Ponta Delgada
Datum zahájení konference
*
:
Typ akce podle státní
příslušnosti účastníků akce
*
:
Celosvětová akce
Kód UT WoS :
EID :
Klíčová slova anglicky
*
:
Goniophotometer; U-Net; Asymmetric segmentation; Car headlamp
Popis v původním jazyce
*
:
We deal with replacing a costly and slow goniophotometer device with a standard, inexpensive, and fast camera in the task of evaluating an illuminated area by a car headlamp. This solution is novel, has not yet been solved, and has the potential to speed up the process of prototyping headlamps. The difficulties lie in the significantly different resolutions of the two devices and in the disparity between intensities captured by the camera and goniophotometer due to the nonlinear behavior of the light. We propose to capture images by a camera with various exposure times and handle them as a multispectral image. The image is processed by U-Net architecture where we replaced the standard decoder with a Hypercolumn rescale block. The proposed scheme produces a mean absolute percentage difference between the real goniophotometer and our solution of less than 0.5\%.
Popis v anglickém jazyce
*
:
Typ zdroje financování výsledku
*
:
Specifický výzkum
Seznam projektů :
ID Projektu
Název projektu
Seznam ohlasů :
Ohlas
R01:
Complementary Content
Deferred Modules
${title}
${badge}
${loading}
Deferred Modules