Typ záznamu * : stať ve sborníku (D)
Domácí pracoviště * : Ústav zobrazovacích metod (11530)
Název * : Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device
Citace : Fiedorova, K., Augustynek, M., Kubicek, J., Penhaker, M., Vodakova, A. a Korhelík, K. Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device. In: 15th Mediterranean Conference on Medical and Biological Engineering and Computing (MEDICON): XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019 2019-10-26 Portugalsko. Cham: SPRINGER INTERNATIONAL PUBLISHING AG, 2020. s. 1599-1608. ISBN 978-3-030-31635-8.
Podnázev :
Rok * : 2020
Obor * :
Počet stran * : 10
Strana od * : 1599
Strana do * : 1608
Forma vydání * : Elektronická verze
Kód ISBN * : 978-3-030-31635-8
Kód ISSN : 1680-0737
Název sborníku * : XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019
Sborník : Mezinárodní
Název nakladatele * : SPRINGER INTERNATIONAL PUBLISHING AG
Místo vydání * : Cham
Stát vydání : Sborník vydaný v zahraničí
Název konference : 15th Mediterranean Conference on Medical and Biological Engineering and Computing (MEDICON)
Místo konání konference * : Portugalsko
Datum zahájení konference * :
Typ akce podle státní
příslušnosti účastníků akce * :
Evropská akce
Kód UT WoS : 000582693600197
EID : 2-s2.0-85075891589
Klíčová slova anglicky * :
X-ray, Secondary radiatio,n Computed radiography cassette, Imaging plate, Multilevel, Otsu method
Popis v původním jazyce * :
Nowadays, the use of X-ray is an important part of imaging techniques used in medicine. The resulting skiagraphy images are kept in the workplace and can be influenced by secondary radiation, which occurs as a secondary effect when irradiated with X-rays. This secondary radiance has not to effect only for the skiagraphy images but also for the human body. The effect of secondary radiation is irreversible image acquisition, which can lead to poor diagnosis and poor clinical information. Currently, there are no techniques and methods available to determine the extent of secondary damage to the skiagraphy cassette. In the work, we analyse the influence of secondary radiation on the quality of the skiagraphy images using mobile X-ray devices. During image analysis, a multi-region segmentation method is used to determine pixels that are affected by irradiation. By this method, we are able to derive the characteristics of the image, determine the level of irradiation and estimate the effect of secondary radiation.
Popis v anglickém jazyce * :
Typ zdroje financování výsledku * : Jiné veřejné zdroje
Seznam projektů :
ID Projektu Název projektu
Seznam ohlasů : 
Ohlas
R01: RIV/61988987:17110/20:A2202D4O

© 2019 Centre for Information Technology

  • Technická podpora :
  • Mgr. Olga Blahutová (phone: +420 597 091 129, phone flap for UO: 1129)
  • Ing. Lucie Svitaneková (phone: +420 597 091 108, phone flap for UO: 1108)
Complementary Content
  • ${title}${badge}
${loading}